DEUTZ Engine Fault Codes DTC list

 

Light Function code / component error

 

123 Access to the lamp cooling temperatures liquids

Wrong signal exceeding the temperature of the device management

126 speed adjustment manually Wrong / unclear signal

128 Intake Air Temperature Sensor Signal Wrong

133 temperature sensor Transmission oil Wrong signal

134 Rail pressure control system Confusing signal pressure / pressure deviation for out of range

135 Exit to the signal lamp oil pressure Wrong signal exceeding the temperature of the device management

Exit to the valve block of the fuel metering Wrong signal exceeding the temperature of the device management

136 Control of air filter air pressure downstream of the filter is too low

137 Output to actuators Short to battery

138 Output to actuators Short circuit on the case

142 Access to the lamp of the engine Wrong signal exceeding the temperature of the device management

143 Multi-position switch 1/2/3 Wrong / unclear signal

144 lubricating oil temperature sensor Wrong / unclear signal Oil Temperature Control The temperature outside the specified range

145 Control switch lock automation Confusing signals

146 Pressure reducing valve Rail System Valve open / required pressure push / push after

Pressure does not open

147 Rail Pressure Sensor Wrong signal pressure deviation outside allowable range

231 Oil Pressure Control Pressure out of range

232 Control of cooling temperature liquids

Temperatures above specified range

233 control intake air temperature above the predetermined temperature range

235 control the coolant level is below a predetermined level range

237 control the fuel temperature Temperature outside specified range

238 Exit to the actuator Fan 1/2

Wrong signal exceeding the temperature of the device management

Control of fan speed speed out of range

241 combustion control detected misfiring in one or more cylinders

261 output to control executive devices

The relay does not open or opens late short ground fault

263 Access to the devices permitting cold start

Wrong signal fault relay jammed or It is not connected, short-circuit

271 CAN Bus timeout of one or more data blocks transmitted, bus inactive

282 Sensor supply voltage 1/2/3 Voltage outside the predetermined range

292 atmospheric pressure sensor Wrong / unclear signal

314 oil temperature sensor hydraulic system Wrong signal oil temperature control for hydraulic system

Temperature is given range

318 Control Battery voltage out of range

328 Access to the lamp control device, facilitating cold start

Wrong signal exceeding the temperature of the device management

414 Output to an external actuator AGR device Wrong signal

415 Output to an external actuator AGR device

Wrong signal exceeding the temperature of the device management

416 Output to an external actuator AGR device Wrong signal

417 Chronometer wear lubricating oil reached a critical juncture

512 Exit to the starter relay Wrong signal exceeding the temperature of the device management

513 Access to the lamp-pointer Wrong signal exceeding the temperature of the device management

514 control terminal 15 signal is not detected

515 control terminal 50 detected a constant signal

521 Speed measurement Speed of movement is incomprehensible

528 Access to the internal engine brake Wrong signal