Troubleshooting of Hyundai Excavator fault code DTC / error code Hyundai 9 series excavators error codes:

 

101 3 hydraulic oil temperature sensor circuit – Voltage above normal or shorted high voltage

 

4 hydraulic oil temperature sensor circuit – Voltage below normal or shorted to low voltage

 

1050 working device (idling) higher than normal pressure sensor data A working device (idling) lower than normal pressure sensor data 2 working device (idle) pressure sensor data error 4 working device (idle) pressure sensor circuit – Voltage below normal or shorted to low voltage

1080 Walking (idling) higher than normal pressure sensor data A walk (idling) lower than normal pressure sensor data 2 Walking (idle) pressure sensor data error 4 Walking (idle) pressure sensor circuit – Voltage below normal or shorted to low voltage

 

1200 primary pump (P1 pump) pressure sensor data is higher than normal A main pump (P1 pump) pressure sensor data below normal Two main pump (P1 pump) pressure sensor data error 4 main pump (P1 pump) pressure sensor circuit – Voltage below normal or shorted to low voltage

 

1210 Main pump (P2 pump) pressure sensor data is higher than normal A main pump (P2 pump) pressure sensor data below normal Two main pump (P2 pump) pressure sensor data error 4 main pump (P2 pump) pressure sensor circuit – Voltage below normal or shorted to low voltage

1220 pressure sensor data overload higher than normal A pressure sensor data overload below normal 2 Overload pressure sensor data errors 4 overload pressure sensor circuit – Voltage below normal or shorted to low voltage

 

1230 a negative feedback pressure sensor data is higher than normal A pressure sensor is a negative feedback data below normal Two negative feedback pressure sensor 1 data errors 4 negative feedback pressure sensor 1 circuit – Voltage below normal or shorted to low voltage

 

1240 Negative feedback data is higher than normal pressure sensor 2 A negative feedback pressure sensor 2 data below normal Two negative feedback pressure sensor 2 data error 4 negative feedback pressure sensor 2 circuit – Voltage below normal or shorted to low voltage

 

1250 pilot pump (P3 pump) pressure sensor data is higher than normal A pilot pump (P3 pump) pressure sensor data below normal Two pilot pump (P3 pump) pressure sensor data error 4 pilot pump (P3 pump) pressure sensor circuit – Voltage below normal or shorted to low voltage

 

1270 boom pilot pressure sensor data to rise higher than normal A large increase in pilot pressure sensor data arm below normal 2 big boom pilot pressure sensor data errors rise 4 arm rose pilot pressure sensor circuit – Voltage below normal or shorted to low voltage

 

1330 arm to the inside / outside and bucket-crowd pilot pressure sensor data is higher than normal A forearm to the inside / outside and bucket-crowd pilot pressure sensor data below normal 2 arm to the inside / outside and bucket-crowd pilot pressure sensor data errors 4 arm to the inside / outside, and a bucket to close the pilot pressure sensor circuit – Voltage below normal or shorted to low voltage